ID
5907
Description
2012 ACCF / AHA Data Standard Chronic Mesenteric Artery Disease data elements see http://www.ncbi.nlm.nih.gov/pubmed/22144570
Link
http://www.ncbi.nlm.nih.gov/pubmed/22144570
Keywords
Versions (6)
- 11/4/14 11/4/14 - Martin Dugas
- 11/11/14 11/11/14 - Martin Dugas
- 11/12/14 11/12/14 - Martin Dugas
- 11/12/14 11/12/14 - Martin Dugas
- 4/13/21 4/13/21 - Dr. rer. medic Philipp Neuhaus
- 9/20/21 9/20/21 -
Uploaded on
November 12, 2014
DOI
To request one please log in.
License
Creative Commons BY-NC 3.0 Legacy
Model comments :
You can comment on the data model here. Via the speech bubbles at the itemgroups and items you can add comments to those specificially.
Itemgroup comments for :
Item comments for :
In order to download data models you must be logged in. Please log in or register for free.
Chronic Mesenteric Artery Disease data elements
Chronic Mesenteric Artery Disease data elements
- StudyEvent: ODM-Test
Description
Physical examination
Alias
- UMLS CUI-1
- C0031809
Description
Describe the patient’s body habitus
Data type
integer
Alias
- UMLS CUI-1
- C1318474
Description
Estimate abdominal aortic diameter by palpation
Data type
float
Measurement units
- cm
Alias
- UMLS CUI-1
- C0579133
Description
Indicate the presence of abdominal bruit
Data type
boolean
Alias
- UMLS CUI-1
- C0221755
Description
Examine the lower rectum to check for abnormalities in the rectum and stool (hemoccult).
Data type
text
Alias
- UMLS CUI-1
- C1384593
Description
Occult blood present?
Data type
boolean
Alias
- UMLS CUI-1
- C0201811
Description
Laboratory Testing
Alias
- UMLS CUI-1
- C0022885
Description
Amylase Indicate the following: ● Date of test ● Value ● Unit of measurement ● Normal range
Data type
float
Alias
- UMLS CUI-1
- C0201883
Description
Lipase Indicate the following: ● Date of test ● Value ● Unit of measurement ● Normal range
Data type
float
Alias
- UMLS CUI-1
- C0523940
Description
Stool fat content ● Microscopic: Indicate the number of stainable lipid globules per high-powered microscope field. ● Gravimetric: Indicate the collection period (number of days), reference range, and test result in grams of lipid per 24 h. ● Titrimetric
Data type
float
Alias
- UMLS CUI-1
- C0202012
Description
Fecal occult blood present?
Data type
boolean
Alias
- UMLS CUI-1
- C0201811
Description
Noninvasive Diagnostic Procedures
Alias
- UMLS CUI-1
- C0259832
Description
Mesenteric Artery Duplex Ultrasound Date of procedure Operator name Peak systolic velocity measurements ● Aorta ● Celiac artery ● Superior mesenteric artery ● Inferior mesenteric artery Ratio of mesenteric artery to aorta peak systolic velocities: Record ratio for celiac, superior mesenteric, and inferior mesenteric arteries. Location of stenosis: ● Celiac artery ● Superior mesenteric artery ● Inferior mesenteric artery Category of stenosis: Specify for celiac, superior mesenteric, and inferior mesenteric arteries. Choose 1 of the following: ● 0–69% ● 70%–99% ● Occlusion
Data type
text
Description
Computed Tomographic Angiography Date of procedure Contrast used: ● Ionic contrast ● Nonionic contrast; specify: — Monomer — Dimer Contrast volume [ml] Artery imaged: ● Celiac artery ● Superior mesenteric artery ● Inferior mesenteric artery Location of stenosis Artery stenosis:Indicate the severity of stenosis by quantitative analysis using the formula 100x(1-minimum lumen diameter)/maximum diameter of reference segment Aneurysm: Dilation of a mesenteric artery to a diameter >=1.5 times the nondilated diameter Thickening of the small or large bowel wall: yes/no Free air in the abdomen: yes/no Mesenteric venous thrombosis: Patent venous opacification of the superior mesenteric vein and portal vein Pneumatosis coli: yes/no
Data type
text
Alias
- UMLS CUI-1
- C1536105
Description
Magnetic Resonance Angiography Date of procedure Contrast use: yes/no Artery imaged: ● Celiac artery ● Superior mesenteric artery ● Inferior mesenteric artery Location of stenosis Artery stenosis: Indicate the severity of stenosis by quantitative analysis using the formula 100x(1-minimum lumen diameter)/maximum diameter of reference segment Aorta: Identify atherosclerosis, stenosis, occlusion, and/or aneurysm of the abdominal aorta. Thickening of the small or large bowel wall: yes/no Free air in the abdomen: yes/no Mesenteric venous thrombosis: Patent venous opacification of the superior mesenteric vein and portal vein Pneumatosis coli: yes/no
Data type
text
Alias
- UMLS CUI-1
- C0243032
Description
Diagnostic Testing: Invasive procedures
Alias
- UMLS CUI-1
- C0430022
- UMLS CUI-2
- C0205281
Description
Date of procedure Operator name Artery imaged: ● Celiac artery ● Superior mesenteric artery ● Inferior mesenteric artery Artery stenosis: Indicate the severity of stenosis by quantitative analysis using the formula 100x(1-minimum lumen diameter)/maximum diameter of reference segment Aorta: Identify atherosclerosis, stenosis, occlusion, and/or aneurysm of the abdominal aorta. Diffuse vasospasm: Indicate the presence or absence of vasospasm consistent with nonocclusive mesenteric ischemia. Mesenteric venous thrombosis: Indicate whether the superior mesenteric vein and portal vein are patent or occluded by thrombus.
Data type
text
Alias
- UMLS CUI-1
- C0002979
Description
Treatment: Invasive Therapeutic Procedures, Catheter-based
Alias
- UMLS CUI-1
- C0087111
Description
Date of procedure Operator name Angioplasty/stenting Choose one: ● Balloon angioplasty alone ● Stent Balloon length [mm] Nominal balloon diameter: Indicate the diameter of the balloon at initial inflation and final inflation in millimeters. How many stents used (per artery)? ● 1 ● >1 Stent type: ● Balloon expandable ● Self-expanding ● Drug eluting ● Covered Stent brand name: Identify the brand name of the stent used. Stent model: Identify the model number of the stent used. Stent manufacturer Identify the manufacturer of the stent used. Stent length Indicate the length of the stent used in millimeters. Stent diameter Indicate the diameter of the stent used in millimeters. Target mesenteric artery Indicate whether the target vessel for the procedure is the celiac, superior mesenteric, and/or inferior mesenteric artery. Current procedure part of clinical trial Indicate whether the procedure is part of a clinical trial. Choose 1 of the following: ● Yes — If yes, indicate the trial type: X IDE X Postmarket approval X Other (specify) ● No Anesthesia Indicate if the patient received general anesthesia, conscious sedation, local anesthesia, or no anesthesia during the current procedure. Procedure Indications and Anatomic Variables Clinical indication ● Symptoms of mesenteric ischemia ● Weight loss ● Malnutrition ● Other Restenosis in target vessel after prior mesenteric artery stent Note if the indication for the current procedure is restenosis in the target mesenteric artery that was previously treated with angioplasty and/or a stent. Contrast volume Indicate the volume of iodinated contrast injected during the procedure in milliliters. Fluoroscopy time Indicate the total fluoroscopy time recorded during the procedure to the nearest 0.10 min. The time recorded should include the total time for the procedure. Procedure arterial access site Indicate the primary arterial access site used to perform the mesenteric artery stenting procedure. Note the location (right/left): ● Femoral ● Brachial ● Radial ● Axillary Arterial access closure method ● List methods and devices in chronological order of closure. ● Indicate the method used to achieve hemostasis: — Device — Nondevice (such as manual compression) Lesions Target lesion location Indicate the location of the target lesion. Visible thrombus present Indicate if the target lesion contains thrombus as assessed by baseline angiography and implied by the presence of filling defect. Calcification Indicate if calcification is present. If present, specify the location. Choose 1of the following: ● None ● Mild ● Moderate ● Severe Lesion length Indicate the length of the target lesion in millimeters as assessed by baseline angiography. Minimal luminal diameter Indicate the MLD of the target lesion in millimeters as assessed by baseline angiography. Diameter of distal mesenteric artery Indicate the diameter of the nontapering distal segment of the mesenteric artery measurement at the intended landing zone of the distal edge of the stent. Preprocedure percent stenosis of mesenteric artery Indicate the severity of stenosis by quantitative analysis using the formula 100x(1-minimum lumen diameter)/maximum diameter of reference segment